High Voltage Generators

---High Voltage Generators
High Voltage Generators 2017-12-20T10:12:47+00:00

Bosello HT develops and produces in its facility at Cassano Magnago a wide range of X-Ray mono-block compact generators and High Voltage generators for different purposes, ranging from its industrial X-Ray systems to OEM applications in different fields, such as medical, food inspection, security.

Their highly stable X-Ray output values make Bosello High Voltage devices appreciated for level measurements as well as thickness gauging.

X-Ray Equipments

Technical Data Sheet

Model name XRG 160-.64 XRG 160-.64 CI XRG 160-1.6 SI XRG 226-1.8 I – XRG 225-3.0 XRG 320-1.8 SI – XRG 320-4.2 I XRG 450-1.5 I – XRG450-4.5 I
Application fields Radioscopy, radiography, CT
Supply mains conditions VAC/ Hz 230 VAC ± 10% single phase 50/60 Hz – max 6 ARMS 230 VAC ± 10% single phase 50/60 Hz – max 16 ARMS 230 VAC ± 10% single phase 50/60 Hz – max 18 ARMS (26 ARMS) 230 VAC ± 10% single phase 50/60 Hz – max 16 ARMS (38 ARMS) 230 VAC ± 10% single phase 50/60 Hz – max 14 ARMS (41 ARMS)
Output Values
Voltage kV 20 ÷ 160 constant potential 20 ÷ 225 constant potential 40 ÷ 320 constant potential (bipolar) 50 ÷ 450 constant potential (bipolar)
kV resolution kV 1
kV accuracy ± 1%
kV stability ± 0.1%
Current mA 0.2 ÷ 10 <
0.2 ÷ 10 ¢
0.2 ÷ 7 0.2 ÷ 10 <
0.2 ÷ 20 ¢
0.2 ÷ 10 <
0.2 ÷ 20 ¢
0.5 ÷ 30 ¢
0.2 ÷ 10 <
0.2 ÷ 20 ¢
0.5 ÷ 25 ¢
0.2 ÷ 5 <
0.2 ÷ 12 ¢
0.5 ÷ 8 <
0.5 ÷ 20 ¢
mA resolution mA 0.1
mA accuracy ± 0.2% ± 1%
mA stability ± 0.1%
Power W 640 <
640 ¢
continuous
autom. limited
640 continuous 640 <
1600 ¢
continuous
autom. limited
800 < 640
1800 ¢ 3000
continuous
autom. limited
800 < 1500
1800 ¢ 4200
continuous
autom. limited
700 < 900
1500 ¢ 4500
continuous
autom. limited
HV connection R24 receptacle socket 2 x R24 receptacle socket
Operating values
Generator control digitally by RS 232, or XRC 600 X-Ray Controller digitally by RS 232 or XRC PU01 controller
Operating frequency kHz 20 (H.V. transformer); 20 (X-Ray tube filament) 25 (H.V. transformer); 25 (X-Ray tube filament) 20 (H.V. transformer); 20 (X-Ray tube filament)
Operating temperature °C 10 ÷ 35
Cooling by air with internal fan
Dimensions (L x W x H) mm 575 x 520 x 185 580 x 375 x 200 575 x 520 x 325 690 x 650 x 360 C = 575 x 520 x 325
A = 575 x 520 x 185
2 x (680 x 700 x 360)
2 x (680 x 700 x 360)
2 x (680 x 700 x 360)
Weight kg 80 60 100 170
200
C = 100 kg A = 80 kg
2 x 200 kg
2 x 200 kg
2 x 200 kg